SA MULTI-TURN ACTUATORS FOR OPEN-CLOSE DUTY
	The following data applies to actuators with 3-phase motors, operated in type of duty S2 - 15 min/classes A and B in compliance with
	EN 15714-2. For further information on other motor types and types of duty, refer to separate technical and electrical data sheets.
	 
| 
				 Type  | 
			
				 Output speeds at 50 Hz1  | 
			
				 Setting range for tripping torque  | 
			
				 Number of starts Starts max.  | 
			
				 Valve mounting flange  | 
		|
| 
				 
  | 
			
				 [rpm]  | 
			
				 [Nm]  | 
			
				 [1/h]  | 
			
				 EN ISO 5210  | 
			
				 DIN 3210  | 
		
| 
				 SA 07.2  | 
			
				 4 – 180  | 
			
				 10 – 30  | 
			
				 60  | 
			
				 F07 or F10  | 
			
				 G0  | 
		
| 
				 SA 07.6  | 
			
				 4 – 180  | 
			
				 20 – 60  | 
			
				 60  | 
			
				 F07 or F10  | 
			
				 G0  | 
		
| 
				 SA 10.2  | 
			
				 4 – 180  | 
			
				 40 – 120  | 
			
				 60  | 
			
				 F10  | 
			
				 G0  | 
		
| 
				 SA 14.2  | 
			
				 4 – 180  | 
			
				 100 – 250  | 
			
				 60  | 
			
				 F14  | 
			
				 G1/2  | 
		
| 
				 SA 14.6  | 
			
				 4 – 180  | 
			
				 200 – 500  | 
			
				 60  | 
			
				 F14  | 
			
				 G1/2  | 
		
| 
				 SA 16.2  | 
			
				 4 – 180  | 
			
				 400 – 1,000  | 
			
				 60  | 
			
				 F16  | 
			
				 G3  | 
		
| 
				 SA 25.1  | 
			
				 4 – 90  | 
			
				 630 – 2,000  | 
			
				 40  | 
			
				 F25  | 
			
				 G4  | 
		
| 
				 SA 30.1  | 
			
				 4 – 90  | 
			
				 1,250 – 4,000  | 
			
				 40  | 
			
				 F30  | 
			
				 G5  | 
		
| 
				 SA 35.1  | 
			
				 4 – 45  | 
			
				 2,500 – 8,000  | 
			
				 30  | 
			
				 F35  | 
			
				 G6  | 
		
| 
				 SA 40.1  | 
			
				 4 – 32  | 
			
				 5,000 – 16,000  | 
			
				 20  | 
			
				 F40  | 
			
				 G7  | 
		
| 
				 SA 48.1  | 
			
				 4 – 16  | 
			
				 10,000 – 32,000  | 
			
				 20  | 
			
				 F48  | 
			
				 –  | 
		
SAR MULTI-TURN ACTUATORS FOR MODULATING DUTY
	The following data applies to actuators with 3-phase motors, operated in type of duty S4 - 25 %/class C in compliance with EN 15714-2.
	For further information on other motor types and types of duty, please refer to separate technical and electrical data sheets
	 
| 
				 Type  | 
			
				 Output speeds at 50 Hz1  | 
			
				 Setting range for tripping torque  | 
			
				 Maximum torque for modulating duty  | 
			
				 Number of starts Starts max.2  | 
			
				 Valve mounting flange  | 
		|
| 
				 
  | 
			
				 [rpm]  | 
			
				 [Nm]  | 
			
				 [Nm]  | 
			
				 [1/h]  | 
			
				 EN ISO 5210  | 
			
				 DIN 3210  | 
		
| 
				 SAR 07.2  | 
			
				 4 – 90  | 
			
				 15 – 30  | 
			
				 15  | 
			
				 1,500  | 
			
				 F07 or F10  | 
			
				 G0  | 
		
| 
				 SAR 07.6  | 
			
				 4 – 90  | 
			
				 30 – 60  | 
			
				 30  | 
			
				 1,500  | 
			
				 F07 or F10  | 
			
				 G0  | 
		
| 
				 SAR 10.2  | 
			
				 4 – 90  | 
			
				 60 – 120  | 
			
				 60  | 
			
				 1,500  | 
			
				 F10  | 
			
				 G0  | 
		
| 
				 SAR 14.2  | 
			
				 4 – 90  | 
			
				 120 – 250  | 
			
				 120  | 
			
				 1,200  | 
			
				 F14  | 
			
				 G1/2  | 
		
| 
				 SAR 14.6  | 
			
				 4 – 90  | 
			
				 250 – 500  | 
			
				 200  | 
			
				 1,200  | 
			
				 F14  | 
			
				 G1/2  | 
		
| 
				 SAR 16.2  | 
			
				 4 – 90  | 
			
				 500 – 1,000  | 
			
				 400  | 
			
				 900  | 
			
				 F16  | 
			
				 G3  | 
		
| 
				 SAR 25.1  | 
			
				 4 – 11  | 
			
				 1,000 – 2,000  | 
			
				 800  | 
			
				 300  | 
			
				 F25  | 
			
				 G4  | 
		
| 
				 SAR 30.1  | 
			
				 4 – 11  | 
			
				 2,000 – 4,000  | 
			
				 1,600  | 
			
				 300  | 
			
				 F30  | 
			
				 G5  |