Application
Turbimax CUS52D is a sensor for measuring turbidity and low solids content in
drinking water and process water applications.
• Turbidity measurement at all stages of the water treatment process
• Final turbidity measurement in outlet of waterworks
• Turbidity measurement in inlet of waterworks
• Turbidity measurement for filter monitoring and filter backwashing
• Turbidity measurement in drinking water networks
• Turbidity measurement in saline media (plastic sensor only)
Your benefits
• Turbidity measurement in accordance with ISO 7027
• The hygienic design with the 2" clamp means it can be mounted directly in pipes
and fits into CUA252 (PE 100) and CUA262 (stainless steel) flow assemblies
• Immersion version can be installed in open channels and basins
• Can be used at high temperatures and high pressures
• Standardized communication (Memosens technology) enables "plug and play"
• Intelligent sensor - all characteristics and calibration values are stored in the
sensor
• Customer calibrations with 1 to 6 points can be performed in the lab or at place of
installation
• Completely safe, as the optical source requires little power to operate
Specifications
| 
					 Measuring range 
  | 
				
					 Turbidity  | 
				
					 0.000 to 4000 FNU Display range up to 9999 FNU  | 
				
					 Formazine  | 
			
| 
					 
  | 
				
					 Solids  | 
				
					 0 to 600 mg/l Display range up to 3 g/l  | 
				
					 Kaolin 
  | 
			
| 
					 
  | 
				
					 
  | 
				
					 0 to 2 200 mg/l Display range up to 10 g/l  | 
				
					 Diatomite  | 
			
| 
					 
  | 
				
					 Temperature  | 
				
					 –20 to 85 °C (–4 to 185 °F)  | 
				
					 
  | 
			
| 
					 Electrical connection  | 
				
					 The following connection options are available: • via M12 connector (version: fixed cable, M12 connector) • via sensor cable to the plug-in terminals of a sensor input on the transmitter (version: fixed cable, end sleeves)  | 
			||
| 
					 Reference operating conditions  | 
				
					 20 °C (68 °F), 1013 hPa (15 psi)  | 
			||
| 
					 Maximum measured error 
  | 
				
					 Turbidity  | 
				
					 2 % of the measured value or 0.1 FNU (the greater value applies in each case). Reference: measured value in recommended operational range, factory calibration  | 
			|
| 
					 
  | 
				
					 Solids  | 
				
					 < 5% of measured value or 1 % of the end of measuring range (the greater value applies in each case). Applies for sensors that are calibrated to the particular measuring range under analysis.  | 
			|
| 
					 Repeatability 
  | 
				
					 < 0.5 % of the measured value  | 
			||
| 
					 Long-term reliability  | 
				
					 Drift Working on the basis of electronic controls, the sensor is largely free of drifts.  | 
			||
| 
					 Response time  | 
				
					 > 1 second, adjustable  | 
			||
| 
					 Process temperature range 
  | 
				
					 Stainless steel sensor –20 to 85 °C (–4 to 185 °F) Plastic sensor –20 to 60 °C (–4 to 140 °F)  | 
			||
| 
					 Process pressure range  | 
				
					 Stainless steel sensor 0.5 to 10 bar (7.3 to 145 psi) (abs.) Plastic sensor 0.5 to 6 bar (7.3 to 87 psi)  | 
			||
| 
					 Flow limit  | 
				
					 Minimum flow No minimum flow required.  | 
			||
| 
					 Ambient temperature range  | 
				
					 –20 to 60 °C (–4 to 140 °F)  | 
			||
| 
					 Storage temperature  | 
				
					 –20 to 70 °C (–4 to 158 °F)  | 
			||
| 
					 Degree of protection  | 
				
					 IP 68 (1.8 m (5.91 ft) water column over 20 days, 1 mol/l KCl)  | 
			||
| 
					 Electromagnetic compatibility (EMC)  | 
				
					 Interference emission and interference immunity as per • EN 61326-1:2013 • EN 61326-2-3:2013 • NAMUR NE21: 2012  | 
			||