Technical characteristics
	•Flow rate up to:
	- 64 l/h for MAXROY® D105
	- 410 l/h for MAXROY® A105
	- 420 l/h for MAXROY® B105
	- 1100 l/h for MAXROY® B145
	•Pressure up to:
	- 10 bar for MAXROY® A105 and B145
	- 28 bar for MAXROY® B105 and D105
	•Maximum temperature of pumped liquid:
	- +90 °C for metallic liquid end
	- +50 °C for plastic liquid end
	•Adjustment of flow rate while running or stopped: from 0 to 100%
	•Accuracy: ± 1% of rated flow from 10% to 100% stroke
	•Internal safety valve, normally set at the factory
	Optional relief valve setting
	•Suction lift: up to 2 m water save for "Viscous Liquids" version
	•Maximum suction pressure condition: 2 bar
	•Working life of the diaphragm can exceed 20,000 hours depending
	on the pumped fluid, working conditions and installation
	•Single or double diaphragm
	•Multiplexing available
	•Can comply with API 675
	•Explosion-proof version is in accordance with ATEX CE II 2 G/D c T4
	(plastic liquid end, please consult us)
	 
	Electrical characteristics of motors
	Standard motor data:
	•Supply: 230/400 V, 3-phase, 50 Hz or 260/460 V, 3-phase, 60 Hz
	•IM V1 mounting, FF130 flange, 14x30 mm shaft for
	MAXROY® A105, B145 and D105
	IM V1 mounting, FF165 flange, 19x40 mm or 24x50 mm shaft
	for MAXROY® B105
	•Protection: IP 55, tropicalized (90%)
	•Insulation: class F
	•Ambient temperature: -16 °C to +40 °C
	•Motor speed:
	- 1000 rpm for MAXROY® A105, B145 and D105
	- 1000 or 1500 rpm for MAXROY® B105
	•Motors are in accordance with national and international
	standards
	•Special or specific motors on request